Product description
Main Applications:
The oil-immersed transformer can adjust the output voltage steplessly, smoothly and continuously under load. It is mainly used in motor and electrical testing, electric furnace temperature control, rectifier equipment matching, generator excitation, etc., and is widely used in machinery manufacturing, chemical industry, textile, communications, military and other industries. Sales Hotline: 13508930968
Features:
1. No contact adjustment, long service life;
2. Suitable for loads of various natures;
3. Strong overload capacity;
4. Reliable operation, easy to use and maintain.
Installation, use and maintenance:
1. Newly installed or long-term oil-immersed transformers must be safe to use at 500V before operation, otherwise they should be hot-baked. The hot drying treatment method can generally take the charged drying method or send it to the drying room to dry, and check whether the fasteners are loose after drying, and if they are loose, they should be tightened.
2. The oil-immersed transformer must be well grounded to ensure safety.
3. It is not allowed to be used in parallel.
4. The input voltage value of this machine shall not exceed the rated voltage, so as not to burn out the machine or electrical equipment, and when the machine is not in use, the output voltage should be adjusted to 0V, and the input power supply should be cut off.
5. The surface of the coil in contact with the brush should be kept clean frequently, otherwise it is easy to cause sparks and burn the surface of the coil.
6. From the power supply to the oil-immersed transformer, the conductor and wire terminal joints from the oil-immersed transformer to the load should be in good contact and can pass the rated current of the oil-immersed transformer.
7. The oil-immersed transformer should always be kept clean, and no water droplets and oil stains are allowed to fall into the oil-immersed transformer.
Applications:
This transformer is widely used in all kinds of lighting power supply, audio equipment, DVD player, multimedia audio, television, small charger, beauty salon equipment, instrumentation equipment, stage lighting equipment, lighting control circuit, air conditioning equipment control circuit, medical equipment, monitoring equipment, automation equipment control circuit, mechanical control circuit, energy-saving equipment control circuit and other small power supply of various equipment.
Technical Indicators
1 Input rated voltage: single-phase 220V ~ 230V or 110V ~ 120V or 380V. 50Hz -60Hz, multi-phase can also be determined by the customer.
2. Output voltage: according to the customer’s parameters
3. Temperature rise: <85 °C
4 Waveform Distortion: <0.1%
5. Dielectric strength: 2000V, no breakdown for 1 minute
6. Insulation resistance: winding resistance to ground insulation resistance single-phase ≥ 2.2MΩ
Terms of use:
1. Ambient temperature: -15°C~+40°C
Runsheng products: quality assurance for 2 years, good service, fast efficiency and high quality
To dear customers: how much V is the input and output, how much current, how much is the line length, how many groups of outputs…. and so on can be customized, need other parameters transformer friends can browse the information of this site or consult our company directly, thank you for charging Zhen 0 electric R4 to ask W7,
Technical parameters
20 | 3 | 50 | 380 | 0-650 | 17.8 | 1180 | 4.6 |
25 | 380 | 0-650 | 22.2 | 1400 | 5.6 | ||
31.5 | 380 | 0-650 | 28 | 1700 | 6.9 | ||
40 | 380 | 0-650 | 35.5 | 2000 | 8.3 | ||
50 | 380 | 0-650 | 44.4 | 2360 | 10.3 | ||
63 | 380 | 0-650 | 56 | 2800 | 12.5 | ||
80 | 380 | 0-650 | 71.1 | 3350 | 15.5 | ||
100 | 380 | 0-650 | 88.8 | 4000 | 19 | ||
125 | 380 | 0-650 | 111 | 4750 | 23 | ||
160 | 380 | 0-650 | 142 | 5600 | 28 | ||
200 | 380 | 0-650 | 178 | 6700 | 34.5 | ||
250 | 380 | 0-650 | 222 | 8000 | 42.5 | ||
315 | 380 | 0-650 | 280 | 9500 | 51.5 | ||
400 | 380 | 0-650 | 355 | 11200 | 63 | ||
500 | 380 | 0-650 | 444 | 13200 | 77.5 | ||
630 | 380 | 0-650 | 560 | 16000 | 95 | ||
6000 | 0-6300 | 57.7 | 17000 | 8 | |||
10000 | 0-10500 | 34.6 | 18000 | 5 | |||
800 | 380 | 0-650 | 711 | 19000 | 115 | ||
6000 | 0-6300 | 73.3 | 20000 | 9.8 | |||
10000 | 0-10500 | 44 | 21200 | 6.2 | |||
1000 | 380 | 0-650 | 888 | 22400 | 140 | ||
6000 | 0-6300 | 91.6 | 23600 | 11.8 | |||
10000 | 0-10500 | 55 | 25000 | 7.5 | |||
1250 | 380 | 0-650 | 1110 | 26500 | 175 | ||
6000 | 0-6300 | 115 | 28000 | 14.5 |